  Millimeter-wave technology is a key enabler for next-generation cellular and satellite communications.  It provides ample margin for performance improvement, but it also creates many challenges. At millimeter-wave (mmWave) frequencies, excessive path loss makes RF power limited and costly. Any skew in a flange connection can cause unwanted reflections that degrade signal quality and power. Also, the components designed for mmWave devices are compact and highly integrated with no place to probe, resulting in the need for radiated tests, also known as over-the-air (OTA) tests. For typical radio applications, the free space path loss (FSPL) formula in terms of dB is expressed as:

  FSPL (dB) = 20*log10(d) + 20*log10(f) - 147.55

       d: distance between the antennas in units of km

       f: carrier frequency in units of GHz

  c: speed of light

   The path loss increases dramatically when the frequency (f) increases. You need to control and calibrate the radiated environment around the test setup.

  HOW DOES THIS IMPACT MEASUREMENTS?

  The excessive path loss at millimeter-wave frequencies between instruments and devices under test (DUTs) results in a lower signal-to-noise ratio (SNR) for signal analysis. Lower SNR makes transmitter measurements challenging, such as error vector magnitude (EVM), adjacent channel power (ACP), and spurious emissions. Figures 1 and 2 compare the impact on EVM measurements with the same setups for high and low input signal levels. As the input signal level decreases, the EVM performance increases.

Better-EVM-performance-for-a-high-SNR-64QAM-signal.jpg

  Figure 1. Better EVM performance for a high-SNR 64QAM signal

Poor-EVM-performance-for-a-low-SNR-64QAM-signal.jpg

      Figure 2. Poor EVM performance for a low-SNR 64QAM signal

     Engineers typically reduce the attenuation of the signal analyzer to improve the SNR. However, even when the input attenuation is set to 0 dB, the SNR can still be too low for accurate signal analysis. So, minimizing any possible path loss is critical for millimeter-wave testing.

  Minimizing any possible path loss is critical for millimeter-wave testing.

  REDUCE SIGNAL PATH LOSS

  Whether you're assessing transmitters, troubleshooting receivers, or analyzing OTA signals, the flexibility of signal analyzer hardware and software lets you create the optimum solution. A flexible solution helps you respond to different input signals: high-power to noise-like, low-frequency to terahertz, and a continuous wave to complex wideband modulation. To measure different input signals, signal analyzers can apply attenuation at higher power levels or a preamplifier at lower power levels.

  Select right signal paths for your test applications

     A signal analyzer offers several RF signal paths: default path, microwave preselector bypass, low-noise path, and full-bypass path. These lower noise, improve sensitivity and reduce signal path loss for a better SNR. Figure 3 shows the various signal paths of a signal analyzer.

  1.Default path: The input travels through the RF attenuator, preamplifier, and preselector before reaching the mixer. It is most useful for measuring low-level signals with a bandwidth under 45 MHz, limited by the bandwidth of the preselector.

  2.Microwave preselector bypass: Bypassing the preselector enables a wideband analysis and a flat spectrum response over the bandwidth of the digitizer.

  3.Low-noise path: Bypass the lossy switches in the preamplifier path and the preamplifiers.

  4. Full-bypass path: Combine the low-noise path and microwave preselector bypass.

A-block-diagram-for-various-signal-paths-of-a-signal-analyzer.jpg

  Figure 3. A block diagram for various signal paths of a signal analyzer

   The components in the default path, such as the attenuators, low-noise amplifier, pre-amplifier, and preselector, help you to optimize the signal levels for various test scenarios. For example, you can turn on or off the low-noise amplifier (LNA) and preamplifier that offers four choices of dynamic range and display averaged noise level (DANL)。 Download the application note, Full Bypass Path for X-Series Signal Analyzers, to learn how to get the best configuration of signal paths for your test.

  Tip: Use the Optimize EVM function in the WLAN and 5G NR X-series measurement applications to quickly get the lowest residual EVM contribution from your X-Series Signal Analyzer. The Optimize EVM function automatically chooses the best hardware settings for mechanical attenuation, IF gain, preamp on/off state. It also optionally enables the Full-bypass path. It will save you from manually fine-tuning the hardware settings.

  Use external mixing — extending frequency ranges and measurement plane

    When you build a millimeter-wave test system, cables and accessories in the path between the signal analyzer and the DUT increase insertion loss. Adding an external mixer is a cost-effective way to extend the frequency range of a signal analyzer and move the test plane close to the DUT to reduce insertion loss caused by the long millimeter-wave signal routing.

  Harmonic mixer

  Signal analyzers send a microwave local oscillator (LO) signal to an external mixer and receive an intermediate frequency (IF) signal from the mixer through the same cable as shown in Figure 4. The analyzer further processes the IF signal with filtering, digitizing, analysis, and display operations similar to those for internal mixed signals.

The-smart-harmonic-mixers-connectivity-setups.jpg

  Figure 4. The smart harmonic mixer's connectivity setups

     For volume production tests, you can use a banded solution for in-band test cases. For example, an RF vector signal analyzer (VSA) and an RF vector signal generator (VSG) are essential for 5G frequency range 1 (FR1) in-band RF test cases. For FR2 in-band tests, the VSA and VSG, used as an IF signal analyzer and signal generator, can be coupled with an external millimeter-wave transceiver, as shown in Figure 5.

5G-FR1-and-FR2-transmitter-and-receiver-test-solution.jpg

  Figure 5. A banded and condensed solution for 5G FR1 and FR2 transmitter and receiver tests

     External mixing provides a cost-effective solution for millimeter-wave signal analysis and moves the test port close to the DUT. However, there is no preselector at the front end of the mixer. Strong out-of-band signals may lead to unwanted images in the band of interest and degrade measurement accuracy.

  Frequency extender

  An advanced external frequency extender integrates a preselector and an RF switch into a high-dynamic-range mixer with the seamless operation interface of the signal analyzer. This solution enables unbanded and preselected swept power spectrum from 2 Hz to 110 GHz without managing band breaks and images, and the IF bandwidth up to 11 GHz. Figure 6 shows the test setups for a signal analyzer and an external frequency extender.

The-N9042B-X-series-signal-analyzer-with-the-V3050A-frequency-extender.jpg

  Figure 6. The N9042B X-series signal analyzer with the V3050A frequency extender delivers unbanded, preselected sweep from 2 Hz to 11 GHz and 11 GHz of analysis bandwidth

       MORE THAN A SINGLE ANSWER

  Millimeter-wave testing means not only higher frequencies but also wider input ranges. Engineers need to take extra care to evaluate millimeter-wave components and devices correctly. Understand your test applications and the test equipment that allows you to make accurate and repeatable measurements.

  In my next blog, I will discuss testing wideband signals at millimeter-wave frequencies. Stay tuned.

  

 

6375694355894054841632232.jpg

本站內容除特別聲明的原創文章之外,轉載內容只為傳遞更多信息,并不代表本網站贊同其觀點。轉載的所有的文章、圖片、音/視頻文件等資料的版權歸版權所有權人所有。本站采用的非本站原創文章及圖片等內容無法一一聯系確認版權者。如涉及作品內容、版權和其它問題,請及時通過電子郵件或電話通知我們,以便迅速采取適當措施,避免給雙方造成不必要的經濟損失。聯系電話:010-82306118;郵箱:aet@chinaaet.com。
主站蜘蛛池模板: 国产午夜精品一区二区三区不卡 | 男女视频免费 | 99精品视频在线观看免费 | 日本欧美亚洲 | 色在线视频观看 | 国产在线欧美日韩一区二区 | 最近中文字幕2019 | 九九久久亚洲综合久久久 | 亚洲国产高清一区二区三区 | 日本一区二区三区欧美在线观看 | 亚洲成av人影片在线观看 | 天天综合天天 | 国产自愉怕一区二区三区 | 国产性大片黄在线观看在线放 | 色偷偷91久久综合噜噜噜 | 国产草比 | 99精品欧美一区二区三区美图 | 日本精品久久久免费高清 | h动态图男女啪啪27报gif | 日日摸人人拍人人澡 | 亚洲综合偷自成人网第页 | 羞羞视频官网 | 两个人免费视频www 两个人看的www中文字幕 | 视频一区二区三区自拍 | 日韩中文字幕在线视频 | 国产一级高清视频 | 国产亚洲精品在天天在线麻豆 | 免费大片av手机看片 | 免费乱理伦片泡泡影院琪琪 | 国产高清在线丝袜精品一区 | 黄色短片视频 | 草草视频免费看 | 色视频网站大全免费 | 福利在线免费视频 | 亚洲五月激情网 | 一级中国毛片 | 日韩手机在线视频 | 卡一卡二卡三精品入口 | 伊人性视频 | 中文字幕一区二区三区免费看 | 经典三级四虎在线观看 |